Space standards and headcount
The per-person figure is the most requested and the most misused number in office planning, because it depends entirely on what is counted. Our space per employee calculator works it against your own floor plate; these answers explain the assumptions behind it.
| Density | Sq ft per person | What it feels like | Suits |
|---|---|---|---|
| Very dense | 55–65 | Tight; meeting provision struggles | BPO, call centre, shift working |
| Efficient | 65–75 | Workable with disciplined booking | Scale-ups, cost-focused corporates |
| Standard | 75–90 | Comfortable; adequate enclosed space | Most corporate floors |
| Generous | 90–120 | Spacious; strong collaboration provision | Consulting, legal, design |
| Premium / HQ | 120–160 | Executive scale, large public areas | Headquarters, client-facing |
All figures are net usable area divided by total headcount, including circulation, meeting rooms, pantry and support space.
How do I calculate seats for a floor plate?+
Take the net usable area, deduct core and circulation of roughly 18–25%, allocate 25–35% for meeting, collaboration and support space, and divide the remainder by the workstation footprint including its circulation — typically 42–55 sq ft per desk. Our seating capacity calculator does this against your dimensions.
What desk size should we standardise on?+
1,400 x 700 mm for a comfortable primary desk, 1,200 x 600 mm where density matters, and 1,050 mm for touchdown or hot-desk positions. Below 1,200 mm a desk cannot carry a monitor, a laptop and a notebook simultaneously, which is the actual test rather than the drawing.
How much circulation do we need between desk rows?+
1,200 mm between the backs of facing chairs as a minimum, and 1,500 mm on a main circulation route. Below 1,100 mm, people seated back to back have to move for anyone passing, which is the most common cause of complaints about a plan that looked fine on paper.
Should we plan for hot-desking?+
Only with attendance data. A sharing ratio of 0.7 to 0.8 desks per person is realistic for genuinely hybrid teams and 1.0 remains right for roles that attend daily. Implementing sharing without measuring actual attendance produces either wasted space or a Tuesday morning where a third of staff have nowhere to sit.
Meeting rooms and enclosed space
How many meeting rooms per 100 people?+
In 2026: five to six rooms for four to six people, two to three larger rooms, one boardroom and seven to nine single phone booths per 100 staff. The booth number has roughly tripled since pre-hybrid norms because so many meetings now have a remote participant. See our meeting room design guide.
What size should meeting rooms be?+
Allow 1.8–2.3 sq m per seated person with 900 mm of circulation behind every chair. That gives 3.6 x 3.0 m for six people and 4.8 x 3.3 m for eight. Rooms sized to the table rather than to the people are nominally larger and used at two-thirds of their rated capacity.
Do we still need a boardroom?+
Most organisations use theirs for eight to twelve hours a month and still want it, because it carries the client-facing function. The question worth asking is whether it can be designed to divide, or to double as a town-hall and training space, which is a ₹3–₹8 lakh decision at fit-out and impossible afterwards.
Why can I hear the meeting room next door?+
Usually because the partition stops at the false ceiling and sound travels over it through the ceiling void. Slab-to-slab construction costs ₹80–₹180 per running foot more and is the fix. The other candidates are an unsealed door, a single-glazed front, and cross-talk through shared HVAC ducting.

Design and build under one accountable roof
Services, acoustics and comfort
What lighting level should an office have?+
300–500 lux at the desk for screen-based work, 500–750 lux where paper documents are read, 300–400 in circulation and 500 in meeting rooms with 300–500 lux vertical on faces for video calls. Uniformity and glare control matter as much as the absolute level.
How do we fix a noisy open-plan floor?+
Absorption, blocking and masking together. An NRC 0.85+ ceiling first, then desk screens and carpet, then slab-to-slab partitions on enclosed rooms, then sound masking at 42–48 dBA where the floor holds more than about 40 open-plan seats. Full detail in our office acoustics guide.
What air conditioning provision do we need?+
Size for the occupied density and the equipment load, not the floor area — a dense floor with dual monitors per desk carries a materially higher internal gain than the base-build design assumed. Fresh air at 8–10 litres per second per person is the comfort figure; less and the afternoon slump is a ventilation problem.
How many power and data points per desk?+
Four power and two data as a working standard, delivered at desk level rather than from a floor box under it. Add a dedicated circuit for any print or server position, and plan the routing before the flooring goes down — retrofitting desk power into a completed floor is disproportionately expensive.
Cost, phasing and change
What does an office cost per seat?+
₹1.4–₹4.5 lakh per seat in 2026, covering fit-out and furniture, depending on density, specification and base-build condition. At 80 sq ft per person and ₹3,000 per sq ft that is ₹2.4 lakh per seat; at 65 sq ft and ₹2,200 it is ₹1.43 lakh.
Is it cheaper to refurbish or relocate?+
Refurbishing an occupied floor typically costs 60–75% of a new fit-out of the same area, but takes 30–60% longer and carries a productivity cost that rarely appears in the comparison. Relocation adds the new fit-out plus reinstatement of the old premises at ₹250–₹700 per sq ft. Model both with the reinstatement included.
How long will the design last before it needs changing?+
Plan for a soft refresh at five to seven years and a substantial reconfiguration at eight to twelve. What extends it is flexibility built in at the start: demountable partitions, a modular power and data grid, and furniture that can be reconfigured without a carpenter.
Can you work with our existing furniture?+
Often, and it is worth assessing before it is written off. Task chairs with functioning mechanisms can be re-upholstered at a fraction of replacement cost, and workstation frames can usually take new tops and screens. What rarely transfers well is storage sized to a different plan.





Selected work by Greenbox Design Studio. Tap any image to enlarge.
Frequently asked questions
How much office space does each employee need in India?+
Seventy to ninety square feet all-in for a standard corporate floor, counting circulation, meeting rooms, pantry and support space against total headcount. Below about 65 sq ft, meeting and circulation provision fails before the desks do, which is why dense plans feel worse than the number suggests.
How many meeting rooms per 100 employees?+
Five to six rooms for four to six people, two to three larger rooms, one boardroom and seven to nine single phone booths. The booth figure is roughly triple the pre-hybrid norm, because a large share of meetings now involve one person speaking to a remote participant.
What is the standard desk size for an office?+
1,400 x 700 mm for a comfortable primary desk and 1,200 x 600 mm where density matters. Below 1,200 mm a desk cannot hold a monitor, a laptop and a notebook at once, which is the practical test. Touchdown and hot-desk positions work at 1,050 mm.
What does an office fit-out cost per seat?+
₹1.4–₹4.5 lakh per seat including furniture, at 2026 Indian metro rates. The arithmetic is density times rate: 80 sq ft per person at ₹3,000 per sq ft gives ₹2.4 lakh a seat, while 65 sq ft at ₹2,200 gives ₹1.43 lakh.
How do we make an open-plan office quieter?+
An NRC 0.85 or better ceiling first, then carpet and desk screens, then slab-to-slab partitions around enclosed rooms, then sound masking at 42–48 dBA on floors above about forty open-plan seats. Absorption alone does not reduce speech intelligibility enough to stop distraction.
Should we design for hot-desking?+
Only against measured attendance data. A ratio of 0.7–0.8 desks per person works for genuinely hybrid teams; roles attending daily still need 1.0. Implementing sharing without measurement produces either empty space or a Tuesday where a third of the team has nowhere to sit.