Free Template

Lighting plan template, layers on separate circuits

A lighting plan is not a list of downlights. It is ambient, task and accent, on circuits that switch separately.

4.9/5 · 127 Client ratings
Updated 19 Sep 2026
✓ Warranty-backed work✓ On-time completion guarantee✓ Design & build under one roof✓ 250+ projects delivered

The fixture schedule

All 25 entries below. The circuit column is the one to argue about with your electrician — it is what makes layered lighting actually work.

Lighting plan — room-wise fixture schedule
RoomLayerFixture typeQtyLumens eachCCTCircuit / control
LivingAmbientCove LED strip, 14 W per metre18 m1,100 / m3000KC1, dimmable
LivingTaskRecessed spot, 7 W, 36 degree87003000KC2
LivingAccentAdjustable spot on the art wall, 5 W, 24 degree34803000KC3
LivingDecorativeFloor lamp on a switched socket18002700KSocket, switched
DiningAmbientCove LED strip9 m1,100 / m3000KC1
DiningTaskPendant over the table, centred11,4002700KC4, dimmable
KitchenAmbientRecessed panel or spots69004000KC5
KitchenTaskUnder-cabinet strip, 10 W per metre3.5 m900 / m4000KC6, separate switch
KitchenTaskSpot over the hob and the sink27004000KC5
Master bedAmbientCove LED strip13 m1,000 / m3000KC7, dimmable
Master bedTaskReading light, wall-mounted, both sides24503000KC8, two-way at bedside
Master bedAccentSpot wash on the bed back panel34803000KC9
Master bedNightSkirting night light on a sensor2802200KSensor, no switch
WardrobeTaskInternal strip on a door sensor4 m700 / m4000KSensor
Master bathAmbientIP44 recessed spot47004000KC10
Master bathTaskMirror light, vertical both sides26004000KC11
Master bathAccentNiche strip in the shower1.2 m700 / m3000KC11
Bedroom 2AmbientCove strip or surface panel10 m1,000 / m3000KC12, dimmable
Bedroom 2TaskDesk light on a switched socket15004000KSocket
Study / WFHTaskLinear over the desk, glare-controlled11,8004000KC13
PassageAmbientRecessed spot36003000KC14, two-way both ends
FoyerAccentSpot on the entrance unit24803000KC15
PoojaAccentWarm spot, no cool source23502700KC16, own switch
BalconyAmbientIP65 wall light26003000KC17
UtilityAmbientSurface LED panel11,2004000KC18

Specify in lumens, not watts. CCT is colour temperature; never mix two temperatures in one sightline.

How to use it

  1. Fill it in before first fix, because every circuit is a wire and every wire is buried.
  2. Separate the layers onto different circuits. Cove, spots and task lighting on one switch is the most common lighting mistake in Indian flats.
  3. Fix colour temperature per room and stick to it. A 3000K cove and a 4000K downlight in the same room look like a fault.
  4. Plan driver access. A cove driver above a fixed ceiling with no access panel means cutting the ceiling to change it.

Three lighting mistakes it prevents

  • One ceiling light per room. It produces a flat, shadowless room and you work in your own shadow at every counter.
  • 4000K in a bedroom. Technically brighter, and nobody can relax in it.
  • No night-light circuit. A 1 W skirting light on a sensor is the cheapest quality-of-life item in the whole plan.

Download the template (PDF) →

Size the fixtures with the lumens calculator and the downlights calculator.

Frequently asked questions

How many lumens does a room need?+

Roughly 250 to 300 lumens per square foot of ambient light in living and sleeping areas, and 400 to 500 lux at a work surface. A 130 sq ft bedroom therefore wants about 35,000 lumens of installed capacity across its layers, most of which will be dimmed most of the time.

What colour temperature should I use?+

3000K in living rooms, bedrooms and dining; 4000K in kitchens, bathrooms, utility and work areas; 2700K in a pooja space and for decorative fittings. Never mix two temperatures within one sightline — it reads as a fault, not as a design choice.

Why do I need so many circuits?+

Because layers only work if they switch independently. Eighteen circuits in a 2BHK sounds excessive until you want the cove on and the spots off while watching television. Each additional circuit costs a few hundred rupees at first fix and is effectively impossible to add later.

Are downlights alone enough?+

No. A grid of downlights gives even, flat, shadowless light that makes a room look like an office. Cove or indirect light provides the ambient layer, downlights and spots handle task and accent, and lamps do the work after dark. All three layers, or the room only ever has one mood.

What CRI should I specify?+

Above 80 everywhere and above 90 in dressing areas, kitchens, bathrooms and anywhere colour is judged. Low-CRI LEDs make skin tones look grey and make a carefully chosen palette look wrong, which is a frustrating way to lose the value of everything else you specified.